Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader
Tel 800.624.5625 [email protected]
in door opening solutions
© Copyright, 2012, all rights reserved PN# 500-10450
Page 1 Rev. B, 02/12
SHEAR ALIGNING MAGNALOCK MODEL SAM2-24
INSTALLATION AND OPERATING INSTRUCTIONS
1 INTRODUCTION
Securitron’s Shear Aligning Magnalock “SAM2-24” is a smaller, 24 Volt (only) version of the
original “SAM” Magnalock and is intended for installations where concealed mounting in the door
and frame is desired. As with the original SAM, the operating features allow self-alignment while
securing the door when it closes. The SAM2 is designed to operate with one-way swing, bi-
directional swing or sliding type doors. On swing type doors the lock installs horizontally in the
top or bottom of the door frame or may be installed vertically in the door frame side. For slider
type door applications the lock must be installed horizontally for proper operation. These units
have also been designed to unlock even if a preload is applied to the door.
2 SPECIFICATIONS
MODEL SAM2-24
Holding Force
600 Lbs [272kg]
Dimensions: Length
7.2" [183mm]
Height
1.15" [29mm]
Depth
0.94" [24mm]
Voltage
24 Volts DC
Current @ 24
VDC
62mA
3 PRODUCT OVERVIEW
Upon unpacking this product, an inventory should be made to ensure that all the required
components and hardware have been included. Along with these instructions and the
installation template, each product should include the following items:
Figure 1 – SAM2-24 Magnalock
Magnalock
Strike Assembly
Hardware Pack
Zobrazit stránku 0
1 2 3 4 5 6 ... 10 11

Shrnutí obsahu

Strany 1

Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 [email protected] in door opening solution

Strany 2 - Page 2 Rev. B, 02/12

PN# 500-10450 Page 10 Rev. B, 02/12 APPENDIX A Troubleshooting Problem Lock Does Not Generate a Magnetic Field Points of Reference Check for

Strany 3 - Page 3 Rev. B, 02/12

PN# 500-10450 Page 11 Rev. B, 02/12 1.2.1 Example A: Using Table 1 (24VDC) Find: - Current Draw .200 Amps - Wire Distance 1000 Feet

Strany 4 - Page 4 Rev. B, 02/12

PN# 500-10450 Page 2 Rev. B, 02/12 3.1 HARDWARE 10X 20X 8X Phillips Flat Head #8 X 3/4” Type “A” Socket Flat Head 8-32 X 1/2” Shim P

Strany 5 - Page 5 Rev. B, 02/12

PN# 500-10450 Page 3 Rev. B, 02/12 5.2 Swinging Door The illustrations in Figure 2 demonstrate a SAM2 installed in a swinging door. This is a

Strany 6 - Page 6 Rev. B, 02/12

PN# 500-10450 Page 4 Rev. B, 02/12  Setting the depth center position of the Magnalock is more critical because there is not a lot of free de

Strany 7 - Page 7 Rev. B, 02/12

PN# 500-10450 Page 5 Rev. B, 02/12 mounting bracket and the flush mount bracket in order to raise the Magnalock above the frame surface. Fi

Strany 8 - Page 8 Rev. B, 02/12

PN# 500-10450 Page 6 Rev. B, 02/12 NOTE: THE SAM2-24 STRIKE ASSEMBLY IS NOT RECOMMENDED FOR USE IN ALUMINUM OR STEEL FRAMED DOORS THAT HAVE A

Strany 9 - Page 9 Rev. B, 02/12

PN# 500-10450 Page 7 Rev. B, 02/12 5.6.3 Soft Core Wood Door Use of the end brackets is recommended when installing the strike assembly on sof

Strany 10 - (800) 624-5625

PN# 500-10450 Page 8 Rev. B, 02/12 5.7.2 Strike Level Adjustment Testing (Energized) Energized adjustment testing of the strike height is impo

Strany 11 - IMPORTANT

PN# 500-10450 Page 9 Rev. B, 02/12 6.4 Electrical Wiring The following diagram, Figure 13, represents the proper electrical wiring connections