Securitron iMXDa_iEXDa QUICK START GUIDE Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Pro domov Securitron iMXDa_iEXDa QUICK START GUIDE. Securitron iMXDa_iEXDa QUICK START GUIDE User Manual [it] Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 4
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Securitron Magnalock Corp. Tel 775.355.5625
550 Vista Boulevard Fax 775.355.5633
Sparks, NV 89434 info@securitron.com
www.securitron.com
© Copyright, 2010, all rights reserved PN# 500-22310
Page 1 Rev. B, 01/10
ASSA ABLOY, the global leader
in door opening solutions
iMXDa/iEXDa QUICK START GUIDE
PRODUCT OVERVIEW
MODEL iMXDa/iEXDa
Holding Force
1200 Lbs 544kg]
Dimensions: Length
12.5" [318mm]
Height 3.63" [92mm]
Depth 2" [51mm]
Dual Voltage 12/24 Volts DC
Current: @ 12VDC 370mA
@ 24VDC 270mA
RECOMMENDED TOOLS
Hammer
Center Punch
Power Drill
Drill bits: 9/64”, 3/16”, 7/32”, 3/8”, and 1/2” (iEXDa)
or 1” (iMXDa) diameters
Wrenches: 7/16” open end (or adjustable), 1/2” box/
open end (or adjustable), 1-1/4” open end
(or 12” adjustable), 3/16” Hex Key (Allen)
and provided 3/32” Hex Key
Pliers, vise grip
Screwdrivers: #1, #2 and #3
Phillips and 1/8” Flat Blade
Masking tape
Fish Tape or Lead Wire
Wire Strippers/Cutter
Multimeter
INSTALLATION
Mounting Configuration
Figure 1 illustrates a common installation on out-swing doors. The lock housing mounts to the
header near the corner opposite the door hinge side. The unit may be mounted horizontally or
vertically. Please use the included product mounting template and the following step-
by-step instructions to successfully install the lock housing and strike.
Figure 1
Typical Section of Installation (iMXDa shown)
To properly install the iMXDa/iEXDa unit, the following conditions should be verified:
The entire mounting area for the lock bracket and housing must be a flat surface.
The installed strike must allow the door to close properly.
The lock (E-laminate) face and strike plate must be aligned so that they are centered.
STRIKE/LOCK ALIGNMENT IS IMPORTANT FOR LOCK SYSTEM STATUS SENSING FUNCTIONS
Sex Bolt & Strike
Mounting Screw
Door Frame & Stop
Door
Strike Plate
Lock Housing
Standard Sex
Bolt
(iEXDa)
Mounting Bracket
Lock Housing
Hardware Pack
SB
-
MXD Sex
Bolt
(iMXDa)
SFP (Not Included)
Mounting Bracket
and Hardware
Rubber Washers
(DPS) Strike
Plate
This Kit Includes
:
Zobrazit stránku 0
1 2 3 4

Shrnutí obsahu

Strany 1 - ASSA ABLOY, the global leader

Securitron Magnalock Corp. Tel 775.355.5625550 Vista Boulevard Fax 775.355.5633Sparks, NV 89434 [email protected]© Copyright, 2010

Strany 2

PN# 500-22310Page 2 Rev. B, 01/10STEP 1 - MOUNTING THE STRIKE PLATEThe strike plate should be mounted prior to the lock housing. Figure 2 below illust

Strany 3

PN# 500-22310Page 3 Rev. B, 01/1022.Pull on the assembly (strike) to align and engage the knurled potion of the sex bolt into thehole.23.While keeping

Strany 4 - Page 4 Rev. B, 01/10

PN# 500-22310Page 4 Rev. B, 01/1011.Assemble the lock back onto the mounting bracket, then using a 3/32” hex wrench tightenthe three (3) set screws al

Komentáře k této Příručce

Žádné komentáře