Securitron EMB_Series Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Pro domov Securitron EMB_Series. Securitron EMB_Series User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 8
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader
Tel 800.624.5625 [email protected]
in door opening solutions
© Copyright, 2011, all rights reserved PN# 500-23130
Page 1 Rev. C, 03/11
ELECTRO-MECHANICAL BAR (EMB) SERIES
INSTALLATION INSTRUCTIONS
1. SPECIFICATIONS
MECHANICAL ELECTRICAL/ENVIRONMENTAL
Physical Size:
Height: 2-5/8” [66mm]
Depth: 1-5/8” [41mm] (from mounting
surface)
Overall Length:
36” Door = 34-1/2” [876mm]
42” Door = 40-1/2” [1029mm]
48” Door = 46-1/2” [1181mm]
Operating Force (Maximum): 15 Lbs. [66.7N]
Maximum Recommended Current:
1.5 Amps @ 30VDC
Environmental (Recommended):
Temperature: 32ºF to 120ºF [0ºC to 49ºC]
Humidity: 10% to 90% RH
2. COMPONENTS
EMB UNIT PACKAGE
MOUNTING HARDWARE
4X – 1/4-20 Blind Nut 4X – External Tooth Washer 2X – End Mount Retainer
4X – 1/4-20 x 1” Long
Phillips Pan Head
1X – Blind Nut Installation Tool 2X – E-clip
T
SB-C
Mounting
Hardware
EMB
Push To Exit
Label
Zobrazit stránku 0
1 2 3 4 5 6 7 8

Shrnutí obsahu

Strany 1 - INSTALLATION INSTRUCTIONS

Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 [email protected] in door opening solution

Strany 2 - Page 2 Rev. C, 03/11

PN# 500-23130 Page 2 Rev. C, 03/11 3. DOOR PREPARATION New Installation:  With the door in the closed position, verify that the bar fits bet

Strany 3 - Page 3 Rev. C, 03/11

PN# 500-23130 Page 3 Rev. C, 03/11 Mounting Diagram Hollow Metal (Aluminum Frame Glass) Door Preparation Shown * NOTE: Drill holes through mo

Strany 4 - Page 4 Rev. C, 03/11

PN# 500-23130 Page 4 Rev. C, 03/11 4. INSTALLATION Mount Bar to Door:  Feed wire cable through hole in door, or route wire through the end

Strany 5 - Page 5 Rev. C, 03/11

PN# 500-23130 Page 5 Rev. C, 03/11 5.1 WIRE ROUTING THROUGH END CAP (OPTIONAL) Drill End Cap:  Determine which bar end cap to feed the flex

Strany 6 - Page 6 Rev. C, 03/11

PN# 500-23130 Page 6 Rev. C, 03/11 6. SHORTENING THE BAR (OPTIONAL) Measure for fit:  Measure the distance between stops on the door frame.

Strany 7

PN# 500-23130 Page 7 Rev. C, 03/11 7. ELECTRICAL CONNECTION Typical Wiring Configurations: The following wiring diagrams are provided as exa

Strany 8 - Page 8 Rev. C, 03/11

PN# 500-23130 Page 8 Rev. C, 03/11 Double Break Wiring Many installations include a controlled access device such as a digital keypad or card r

Komentáře k této Příručce

Žádné komentáře